Article The current location: Home > References and Applications > Application of maximum bubble pressure surface tensiometer to study protein-surfactant interactions.

Application of maximum bubble pressure surface tensiometer to study protein-surfactant interactions.

Number of hits:13178    Release time:2020-08-25 00:00:00

 Dixit N, Zeng DL, Kalonia DS.

Source

Department of Pharmaceutical Sciences, School of Pharmacy, University of Connecticut, 69 N Eagleville Road, Unit 3092, Storrs, CT 06269, USA.

Abstract

Binding of a surfactant to proteins can affect their physicochemical stability and solubility in a formulation. The extent of the effect depends on the binding stoichiometry. In this study, we have utilized the technique of maximum bubble pressure surface tensiometry to characterize the binding between human serum albumin (HSA) and surfactants (sodium dodecyl sulfate (SDS) and polysorbate 80) by dynamic surface tension measurements. Results show that two classes of binding sites are present in HSA for SDS, 5 primary binding sites with high binding affinity (K(a)=5.38×10(5)M(-1)) and 12 secondary binding sites with low affinity (K(a)=6.7×10(4)M(-1)). The binding is high affinity and limited capacity due to both, ionic and hydrophobic interactions between HSA and SDS. For polysorbate 80, the binding does not follow the Scatchard plot, and is low affinity and high capacity, indicating that polysorbate 80 interacts with HSA through hydrophobic interactions. The results show that maximal bubble pressure surface tensiometry is a fast and convenient technique to determine the concentration of free and bound surfactants in the presence of proteins.

http://www.ncbi.nlm.nih.gov/pubmed/22985604

Copyright © 2012 Elsevier B.V. All rights reserved.

Hot keywords of USA KINO:contact anglecontact angle measurement,  contact angle meter,  contact angle goniometer,  surface tensiometer, interfacial tensiometer,  surface tension measurement,  surface tension, surface tensiometry, contact angle measurement equipment and device, calculating surfac free energy, Determining Critical Micelle Concentration (CMC) of surfactant, made in China Method for choosing surface tensiometer NEW Method for choosing contact angle meter (goniometer) NEW Method for choosing interfacial tension meter NEW

Manage  technical support: www.chem17.com   GoogleSitemap

MainPro : contact angle,contact angle meter,contact angle goniometer,surface tension,surface tensiometer

Copyright © 2020 KINO Scientific Instrument Inc.  ICP:
Telephone
  • +1 (857) 626-5666