LC-1620 system incorporates advanced and innovative design elements which endow it high reliability and accuracy for long time operation. The working mode of LC-1620 pump is in-parallel. It offers improved accuracy and duration in LC-1620 system. The flow cell of LC-1620 detector is also redesigned and optimized, which offers excellent S/N ratio performance.
LC-1620A system offers analytical flexibility. It provides a comprehensive selection that can be combined to make up a variety of systems for different demands.
High-performance for long time operation
- LC-1620 system incorporates advanced and innovative design elements which endow it high reliability and accuracy for long time operation. The working mode of LC-1620 pump is in-parallel. It offers improved accuracy and duration in LC-1620 system. The flow cell of LC-1620 detector is also redesigned and optimized, which offers excellent S/N ratio performance.
- The whole design and manufacturing process is performed by Chinese engineers. From manufacturing to installation, the system arrives from the factories with restrict validation and test. Its innovative design, engineering and manufacturing features translate into the high accuracy, reliability and quality.
Flexible Configuration
- LC-1620A system offers analytical flexibility. It provides a comprehensive selection that can be combined to make up a variety of systems for different demands.
Choice of Pumping System
- Isocratic system.
- High-pressure binary gradient system.
Choice of Detection System
- UV Detector for routine analysis.
- RID for universal detection in isocratic analysis, especially necessary in GPC system.
- ELSD for universal detection, especially necessary in standard methods in pharmacopeia of China.
Features and benefits
- All maintenance parts are accessible from the front panel for quick replacement without disassembling instrument.
- The monitoring system will stop the pump if pre-limit pressure is exceeded.
- All components are controlled intelligently in workstation.
- On line detect all signal curves, such as the pressure curve, gradient curve and solvent consume warning.
- The interface is open design that it is compatible with other universal workstation.
LC-1620 Pump |
Flow rate range |
0.001-9.999 mL/min |
Flow rate accuracy |
≤±0.5%(1mL/min, water, room temperature) |
|
Flow rate stability |
RSD≤0.08%(1mL/min, water, room temperature) |
|
Peak operating pressure |
45MPa |
|
Power source |
110V/220V |
|
LC-1620 UV Detector |
Lamp |
D2 |
Wavelength range |
190-700nm |
|
Baseline noise |
≤±0.8×0-5AU |
|
Baseline drift |
≤1×10-4AU/h |
|
Limit of detection |
0.4×10-8g/mL(Naphthalene/methyl alcohol solvent) |
|
linearity range |
≥104 |
|
Wavelength repeatability |
0.1nm |
|
Wavelength accuracy |
±1nm |
|
Power source |
110V/220V |
Hot keywords of USA KINO:contact angle, contact angle measurement, contact angle meter, contact angle goniometer, surface tensiometer, interfacial tensiometer, surface tension measurement, surface tension, surface tensiometry, contact angle measurement equipment and device, calculating surfac free energy, Determining Critical Micelle Concentration (CMC) of surfactant, made in China Method for choosing surface tensiometer NEW Method for choosing contact angle meter (goniometer) NEW Method for choosing interfacial tension meter NEW