Products The current location: Home> Products> Analytical Instrument > Gas Chromatography

Gas Chromatography

Updatetime: 2014-01-19 19:19:36

mode: GC1120

Quotation:

Features: Gas Chromatography is a standard instrument that made in China. It is your best choice due to its high quanlity & reasonable price.

Overview Application Features Specification

Gas Chromatography is a standard instrument that made in China. It is your best choice due to its high quanlity & reasonable price.

 

Column oven                            

Temperature range:

Ambient temperature: +7~ 400(increment 1)

Temperature control accuracy: better than±0.1

Temperature program ramps: 5 ramps in total

Program setting: 0.1~40/min(increment 0.1)

Maximum run time: 655 minutes (increment 1min)

 

Hydrogen flame ionization detector (FID)

Minimum detectable level: Dt≤8×10-12 g/s (n-hexadecane)

Drift: ≤6×10-13 A/h

Linear dynamic range: ≥106

Maximum temperature: 400

 

Thermal conductivity detector (TCD)

Sensitivity: S≥5000mv.ml/mg (n-hexadecane)

Tiptop Sensitivity: S≥10000mv.ml/mg (with amplifying circuit)

Noise: ≤20μV

Drift: ≤30μV/h

Linear dynamic range: ≥104

Maximum temperature: 400

 

 

Flame photometric detector (FPD)

Minimum detectable level:

≤1×10-11 g/s (P) (Parathion-methyl)

≤1×10-10 g/s(S) (Parathion-methyl)

 

Electron capture detector (ECD)

Minimum detectable level: ≤1×10-13 g/ml (γ-666)

Linear dynamic range: ≥103

 

Nitrogen phosphorus detector (NPD)

Minimum detectable level:

≤5×10-12 g/s (N) (Diphenyl-Diazene)

≤5×10-13 g/s (P) (Malathion)

 

Instrument operational requirement

Power source: 220V~±22V 50Hz ± 0.5Hz

Power: ≤2000W

Ambient temperature: +5~ +35

Relative humidity: ≤85%


Message box

  • Products:

  • Message content:

  • Your organization:

  • Your name:

  • Contact number:

  • Email:

  • Address:

  • Province:

  • Verification Code:

Hot keywords of USA KINO:contact anglecontact angle measurement,  contact angle meter,  contact angle goniometer,  surface tensiometer, interfacial tensiometer,  surface tension measurement,  surface tension, surface tensiometry, contact angle measurement equipment and device, calculating surfac free energy, Determining Critical Micelle Concentration (CMC) of surfactant, made in China Method for choosing surface tensiometer NEW Method for choosing contact angle meter (goniometer) NEW Method for choosing interfacial tension meter NEW

Manage  technical support: www.chem17.com   GoogleSitemap

MainPro : contact angle,contact angle meter,contact angle goniometer,surface tension,surface tensiometer

Copyright © 2020 KINO Scientific Instrument Inc.  ICP:
Telephone
  • +1 (857) 626-5666